3 power requirements, Power requirements – Daktronics Galaxy AF-3400 34 mm Monochrome/RGB User Manual
Page 18
6. Connect the grounding electrode conductor at the grounding lug on the back of the
display. If the display has two faces, a ground will need to be connected to each
display face.
7. Signal cable is routed to the signal termination enclosure. A grounding electrode
may also be connected there when required.
8. Signal into the enclosures must be routed through 1/2"conduit.
9. The signal quick-connect cable from the enclosure to the display can be routed
through conduit or through the display pole.
Note: Daktronics strongly recommends that the quick-connect cable be secured to protect it
from weather and vandalism.
3.3 Power Requirements
Note: Conductors of circuits delivering power to a Daktronics display shall be sized
in accordance with NEC and local electrical codes so that the power distribution
system is capable of delivering full load power to the display while maintaining a
voltage within 5% of the utility nominal voltage.
Each display uses a 120VAC or 120/240 VAC single-phase power source. Proper power
installation is imperative for proper display operation. Basic power information for various
display sizes can be found in the power specifications charts located in Appendix A. The
following sub-sections provide details for display power installation.
Main Disconnect
The National Electrical Code requires the use of a lockable power disconnect near the
display. Provide a lockable disconnect switch (knife switch) at the display location so that all
power lines can be completely disconnected. Use a 3-conductor disconnect so that both hot
lines and the neutral can be disconnected. The main disconnect should be mounted at or near
the point of power supply connection. A main disconnect is to be provided for each supply
circuit to the display.
The disconnecting means must be located in a direct line-of-sight from the display or outline
lighting that it controls. This requirement enables a worker to keep the disconnecting means
within view while working on the display.
Exception: Disconnect components that are capable of being locked in the open position may
be located elsewhere.
Power Installation
10