Optional Temperature Sensor Mounting

ED-14377-Rev 4

3 October 2007

CAN Temperature

Sensor (TB1)

Field

Cabling

Primary -

Controller Board

CAN US (A31-TB4)

Pin 1 (+5V CAN)

Red

Pin 1 (+5V CAN)

Pin 2 (CAN H)

Green

Pin 3 (CAN H)

Pin 3 (CAN L)

White

Pin 4 (CAN L)

Pin 4 (GND CAN)

Black

Pin 2 (GND CAN)

Shield

Pin 2 (Shield)

1.4 Temperature Interconnection Between Displays

If the display uses the quick-connect interconnect cable, this connection is already complete.

If the interconnect cable was not used, a 4-conductor shielded cable is needed to terminate
the temperature sensor from side one to side two. One end terminates at the “CAN US/DS”
8-position terminal block (A31-TB4) on the Primary display. The other end terminates at the
“CAN US/DS” 8-position terminal block (A31-TB4) at the second Primary display. Refer to
Figure 9 and the table for correct interconnect locations.

Figure 9:

CAN Controller Interconnect


Primary - CAN

DS (A31-TB4)

Field Cabling

Secondary - CAN

US (A31-TB4)

Pin 7 (CAN H)

Green

Pin 3 (CAN H)

Pin 8 (CAN L)

White

Pin 4 (CAN L)

Pin 6 (GND CAN)

Black

Pin 2 (GND CAN)

Pin 5 (Relay)

Red

Pin 1(CAN +5V)

Shield













This manual is related to the following products: