beautypg.com

Power connection, Power connection -7 – Daktronics Galaxy 46 mm Outdoor Series AF-3400 User Manual

Page 31

background image

Figure 16: Installation with Ground and Neutral Conductors

Power Connection

Reference Drawings:
Schematic, Power Term Panel, 1 circuit ............................ Drawing A-211950
Schematic, Power Term Panel, 2 circuit ............................ Drawing A-211947
Schematic, Power Term Panel, 4&6 circuit ........................ Drawing A-223673
Schematic, Power Term Panel, 8 circuit ............................ Drawing A-231469

Display power is connected to the power termination panel in the display. Complete
the following steps to terminate the hot, neutral and ground wires at the termination
panel. The display is equipped with 3/4" knockouts. If these are not sufficient, size
the hole to match the conduit size required.

Route the power cable through conduit to the rear of the display and into the power
termination panel.

Note: the following colors are used for the pre-terminated wires (2 position panel
only):

Line 1 – Black (Brown – 240V)

Line 2 – Red (only on three wire installations – 120/240V)

Neutral - White (Blue – 240V)

Grounding Conductor - (Green-Yellow)

Electrical Installation

3-7

This manual is related to the following products: