beautypg.com

Transformer and rfi filter, Transformer, Transformer and rfi filter -8 – Daktronics Galaxy 46 mm Outdoor Series AF-3400 User Manual

Page 42: 32x96 -8

background image

Transformer and RFI Filter

Reference Drawings:

Schematic, Power Term Panel, 1 Circuit............................... Drawing A-211950
Schematic, Power Term Panel, 2 Circuit............................... Drawing A-211947
Schematic, Power Term Panel, 4&6 Circuit, 120/240 V........ Drawing A-223673
Schematic, Power Term Panel, 8 Circuit, 120/240V ............. Drawing A-231469

Note: Z Filters (refer to Figure 28) are external from the power termination panel.
Refer to layouts to see if there are external Z filters.

Figure 28: RFI Filter Assembly for RGB

displays larger than 32x96












Remember:
Disconnect power before servicing any internal components

Transformer
The transformer is located in the upper portion of the primary display’s power
termination box as shown in Figure 29 and Figure 30. Turn off power to the
display before removing the wires
.

Figure 29: Primary Display Power Termination Box

Figure 30: Power Termination - Displays Larger

than 32x96

Maintenance and Troubleshooting

4-8

This manual is related to the following products: