Section 5: start-up procedure, 1 start-up checklist, 2 start-up sequence – Daktronics Galaxy AF-3500 Series Double Face User Manual
Page 15: 3 post installation checklist, Section 5, Start-up procedure, Start-up checklist, Start-up sequence, Post installation checklist

Start-Up Procedure
11
Section 5: Start-Up Procedure
Before starting up the display, review this checklist to ensure that all parts are ready to operate correctly.
5.1 Start-Up Checklist
• Confirm that power is correctly connected to the display.
• Allow for sufficient power as listed in the display Shop Drawing and Power Specs.
• Assure a main disconnect switch is used to control power.
• Inspect all circuit breakers (internal and external) for sufficient marking and size.
• Confirm that adequate grounding is installed. Each display face must have a separate earth-ground
conductor with a resistance of 10 Ohms or less.
• Assure the external communication equipment (signal enclosure, client radio, etc.) is properly installed.
• Inspect signal connections at the control computer.
• Inspect signal connections at the display.
• Inspect signal connections between displays when necessary.
• Confirm that the control computer is correctly configured.
Follow the step-by-step directions in the Venus
®
1500 Help File’s Configuration section for correct setup.
• Inspect peripheral equipment (temperature sensor, etc.) for proper installation.
5.2 Start-Up Sequence
Each time the display is turned on, an initialization sequence
runs, showing the information in the right column below.
Note: The Xs refer to numbers that vary for each display,
such as the hardware address.
5.3 Post Installation Checklist
Verify the following after starting the display:
• Assure all ventilation fans are fully operational.
• Inspect all intake and exhaust vents for obstructions.
• Confirm proper communications from the control
computer to the display(s).
• Assure proper communications between display
faces when applicable.
Topic
Information Shown
Product Name
Galaxy
Display Size
#Rows x #Columns
Shading/Color Depth
4096 (Mono) or 68B (RGB)
Bootloader Version
OS X.XX
Firmware Number
DD1425608
Firmware Revision
Rev X.XX
Hardware Address
HW:XX
Software Address
SW:XX
IP Address:
(default) IP:172.16.192.25
Subnet MSK:
(default) MSK: 255.255.0.0
COM1 Configuration
C1: 115200
COM 2 Configuration C2: RTD
Socket 3001
IP 3001: 115200
Socket 3002
IP 3002: RTD
Line Frequency
CLK: AUTO (60)
Display Description
Galaxy #Rows x #Columns