beautypg.com

Section 3: power installation, 1 conduit, 2 overview of power/ signal connection – Daktronics Galaxy AF-3200 34 mm User Manual

Page 12: Section 3, Power installation -1, Conduit -1, Overview of power/ signal connection -1

background image

Section 3:

Power Installation

Read the Mechanical, Power, and Signal Installation sections

before installing the display(s).

Only a qualified individual should terminate power and signal cable at this

Daktronics display.

All proposed changes must be approved by Daktronics engineering staff or

the warranty will be rendered null and void.

3.1 Conduit

Daktronics does not include the conduit. Separate conduit must be used to route:

power

signal IN wires to the signal termination enclosure, when applicable

signal OUT wires (if not using the provided interconnect cable)

The power J-box is provided with 3/4” threaded holes for use with 3/4” conduit.
Unthreaded 1/2" knockout holes are provided in the signal enclosures used with the
display. If not using the provided enclosures, use the knockout/ drill holes provided
in the display cabinet.

3.2 Overview of Power/ Signal Connection

Following is a brief summary of the power and signal connections to the display.

1. Enclosures are provided with the display for termination of both signal and

power. If the installation of the display does not allow for the use of these
enclosures, refer to Section 3.5 for diagrams on internal wiring for the
power.

2. Possible methods for signal termination are shown in the manual for the

specific communication type.

3. Route power to the display through a fused disconnect switch capable of

opening all ungrounded power conductors. Install this disconnect within the
line-of-sight of any personnel performing maintenance on the display. If the
disconnect is located out of sight of the display, it must be capable of being
locked in the open position.


Note for 1 and 2 circuit power termination panels:
Displays are equipped with
supplemental protection devices that carry a UL1077 (IEC 60947, VDE 660) rating.
These devices are only intended to protect the components within the display.
Suitable devices must be used for the equipment and feeders supplying power to the
display.

4. Power conductors from the disconnect to the display should be routed

through conduit in agreement with local code.

5. Display power will terminate to the display at the external power

termination J-box mounted to the back of the display. If the display has

Power Installation

3-1