2 functional test, Functional test, On 3.2 ) – Daktronics T-7060 Touchpad User Manual
Page 12

6
Electrical Installation
3.2 Functional Test
1. Plug the touchpad into the touchpad input on the lane module or deck plate. Make sure
that the GND tab on the touchpad connector is lined up with the black jack on the lane
module/deck plate touchpad input.
2. Make sure that the lane modules/deck plates are connected to the OmniSport 2000
console and the console is powered on.
3. Enter the swimming mode of the OmniSport 2000 console and select Menu 5, then 2 to
display the lane data test menu. When the touchpad is pressed, a “T” should flash for 2
seconds in the lane corresponding to the touchpad.
4. With the touchpad hanging in place on the pool wall, bend down and with an open hand,
touch the touchpad with just finger tips. Do this by brining the hand in with the same
amount of energy a swimmer in the water would have. If this is done too lightly, or to
slowly, expect that a touch may not register. Also, because the touchpad needs to charge
back up, count “1001, 1002, 1003” before touching again.
5. Watching the lane data test screen, repeat this test across the entire touchpad surface,
from left to right and top to bottom. This will ensure that there are no dead spots in the
touchpad.