40 pgmⅢ programmable ethernet control system – CREATOR CR-PGMIII User Manual
Page 47

CREATOR CHINA 2011-03
WWW.CREATOR1997.COM
40
PGMⅢ Programmable Ethernet Control System
LEVEL_EVENT(tp7600,1)
{
SEND_M2M_LEVEL(“192.168.1.10”,2,LEVE
L.Value);
SEND_M2M_LEVEL(“192.168.1.2”,12,LEVE
L.Value); // send the touch panel’s bar data 13
with the joint number of 12 to the controller with
the IP of 192.168.1.2
}
BUTTON_EVENT(tp7600,1)
{
PUSH()
{
SEND_M2M_DATA(“192.168.1.2”,”11111”);
//send character 11111 to the controller with the IP
of 192.168.1.2
SEND_M2M_JNPUSH(“192.168.1.2”,12); //
send the touch panel’s joint number 12 to the
controller with the IP of 192.168.1.2
SEND_M2M_JNRELEASE(“192.168.1.2”,12
);// send release command of the touch panel’s
joint number 12 to the controller with the IP of
192.168.1.2
//
}
}
//
send the data of the 2
nd
way of the COM
interface to the controller with the IP of
192.168.1.10
DATA_EVENT(com,2)
{
ONDATA()
{
SEND_M2M_DATA(“192.168.1.10”,BYTES_
TO_STRING(DATA. Data));
}
}
M2MDATA_EVENT()
{
ONDATA()
{
TRACE(“all
ip:”+DATA.STR_M2MIPADDR +” data:” +DATA.
Data String);
}
}
M2MDATA_EVENT(“127.0.0.1”)
{
ONDATA()
{
TRACE(“dai
ip
ip:”+DATA.STR_M2MIPADDR +” data:” +DATA.
DataString);
int p = DATA.B1;
string ip =
DATA.STR_M2MIPADDR;
}
}
M2MDATA_EVENT(“127.0.0.11”)
{
ONDATA()
{
}
}
DEFINE_CALL_TEMPLATE
abc(tpx,3,5,com,4);