17 pgmⅢ programmable ethernet control system – CREATOR CR-PGMIII User Manual
Page 24

CREATOR CHINA 2011-03
WWW.CREATOR1997.COM
17
PGMⅢ Programmable Ethernet Control System
voltage/100.00
DATA_EVENT(mcar,2)
{
ONDATA()
{
double
tt
=
BYTES_TO_INT(DATA.Data)/100.0 //when using
SEND_QACAR to send the request, it triggers
here.
SEND_COM(COM,1,DOUBLE_TO_STRING(tt));
}
}
SEND_ACAR
void SEND_ACAR(String dev,int channel,int val)
Function: control the voltage output of the
Conversion Card.
Parameters:
dev
-
:
Conversion
Card
Device
channel
-
:
Device’s
Channel
number
val - :Analog Value (Notice: read value according
the actual external equipment. The general value
reading range is -12V ~ 12v in double type.)
Example:
acar_L = L:7:ACAR:192.168.1.20; //Define ACAR
Device
with
CRLINK(CAN)
number
of
7
SEND_ACAR(
acar_L,1,-12);//
Send Analog
Value -12 to lilt_L’s first channel. i.e., set the
Converter Card’s output to -12V.