3pgmⅢ programmable ethernet control system – CREATOR CR-PGMIII User Manual
Page 10

CREATOR CHINA 2011-03
WWW.CREATOR1997.COM
3
PGMⅢ Programmable Ethernet Control System
learned for controlling.
6) REBOOT—— Reboot button
Press this button to reboot the system when the
controller is not functioning.
7) DATA—— Data Signal Indicator
The indicator will be ON if the data signal
transmission is normal, or, it will be OFF
8) IR OUT—— IR Signal Indicator
Indicating 8 IR Modules status: when the
controller is sending the IR Control Signal to the
equipment to be controlled, the corresponding
indicator will be ON.
9) COM Interfaces
8 programmable two-way serial communication
DB9 (male) interfaces have been provided;
RS-232/422/485 protocols.
10) ETHERNET—— Ethernet Interface
Used to communicated with the Ethernet and the
Wifi touch panels, or to realize the Ethernet
remote control.
USB——USB2.0 Communication Interface
Connected to the PC’s USB interface to realize
various
operations:
such
as
the
program
downloading, System Diagnosis, and IR Learning,
etc.
11) 24V Safety
12) AC 100V~240V—— System Power Supply
Power Supply for the controller: self-adaptive
AC100V~240V@ 50/60H.
13) IR OUT—— Extension IR Control Module
Slot
Extension IR Control Module can be inserted here
to extend the total IR Control Modules.
14) CR-LINK——CREATOR High-speed Bus
Interface, for extending controlling functions
CR-NET——CR-NET Bus
CREATOR Communication Interface (Similar to
RS485) of 4-core phoenix connector type; can be
used to connecting various CREATOR external
network equipment: such as the relay box,
lighting control module, sound control module,
wireless Access Point, and wired touch panels,
etc.
IR OUT——IR Control Port
Includes 8 ways independent programmable IR
Control
carrier
waves
to
control
various
equipment: such as the DVD, VCR, and MD, etc.
It’s of the 2-core phoenix connector type, and
needs to be used along with the IR Emitting
Probes: connect the IR Emitting Probe to the IR
OUT port and the other end near to the
equipment to be controlled (the distance needs to
be
≤
15cm).
RELAY
OUT——Low-current
Relay
Control Port
Provides 8 ways low-current control function, and
can drive the load below AC 0.3A/125V and DC
0.3A/110V,
DC 1A/30V. It can control the ON
and OFF of any equipment fulfilling the above
mentioned
conditions
to
realize
controlling
high-current, high-voltage load with low-current,
low-voltage controller
DIGITAL I/O——I/O ( input / output )
interface
Provides 8 ways programmable I/O controlling
function: 5V/10mA output or 0~5V/10mA input.
15 ) RELAY OUT——Extension Low-current
Relay Module Slot
Can extend the low-current relay module number
by inserting extension module.