Modbus operation, Modbus registers, Write/read – Contemporary Control Systems EISC Configurable Switches User Manual User Manual

Page 33: 2 modbus, Operation, 3 modbus, Registers, 1 write/read

background image

TD021000-0MB

33

9.2

Modbus Operation

For Modbus operation, the EIA-232 parameters must be set as follows :

Baud Rate = 9600 bps, Data Bits = 8, Stop Bit = 1, No Parity

9.3

Modbus Registers

9.3.1

WRITE/READ

40001-40016: Port Settings:

Auto-negotiation or set speed/duplex per port

Bit 0 – Auto-negotiation (enabled = 1, disabled = 0) – default = 1

Bit 1 – 10Mbps(0) or 100Mbps (1)

Bit 2 – Half duplex (0) or full duplex (1)

Bit 3 – Enable full duplex flow control (enabled = 1, disabled = 0) – default = 1

40001: Port Settings port 1
40002: Port Settings port 2
40003: Port Settings port 3
40004: Port Settings port 4
40005: Port Settings port 5
40006: Port Settings port 6
40007: Port Settings port 7
40008: Port Settings port 8
40009: Port Settings port 9
40010: Port Settings port 10
40011: Port Settings port 11
40012: Port Settings port 12
40013: Port Settings port 13
40014: Port Settings port 14
40015: Port Settings port 15
40016: Port Settings port 16