Installation, Hardware, Mounting – Contemporary Control Systems EISC Configurable Switches User Manual User Manual
Page 11: 1 hardware, 1 mounting

TD021000-0MB
11
5
Installation
5.1
Hardware
5.1.1
Mounting
The EISC is designed for mounting in an industrial enclosure or wiring closet using
either set of the provided mounting hardware listed below:
TS-35 DIN-rail Mounting
Panel Mounting
DIN-rail clip
Panel mounting bracket
DIN-rail clip support bracket
4-40 screws, flat-head (4)
4-40 screws, pan-head (2)
For quick snap-mounting to 35 mm DIN-rail, a reinforced DIN-rail clip is pre-attached to
the back of the EISC enclosure with two #4-40 pan-head screws. If the clip is removed,
the EISC can be panel-mounted by extending the top and bottom brackets which are
shipped in retracted position. The extended brackets can then anchor the EISC to a
wall or other flat vertical surface with two #8 pan-head screws (not provided). The left
illustration of Figure 2 shows a rear view of the EISC with brackets in retracted position.
The right illustration of Figure 2 shows the brackets extended and secured to the EISC
enclosure with the same screws used in retracted position.
Figure 2 — Using the Panel-Mounting Brackets