Comtech EF Data RAP-100 User Manual
Page 30

RAP-100 Remote Access Panel
ODU Operation
Rev. 1
3–13
3.2.47 (ODU,ENABLE,1:1,CSAT#1,MONITOR)
PWR
SUPP2
(ODU,ENABLE,1:1,CSAT#2,MONITOR)
PWR
SUPP2
(ODU,ENABLE,STAND-ALONE,MONITOR)
PWR SUPP2
PS: +5V=5.5 -5V=-4.9
This window provides a monitor for the remaining two internal power supplies, press
ENTER.
3.2.48 (ODU,ENABLE,1:1,CSAT#1)
ALARMS
(ODU,ENABLE,1:1,CSAT#2)
ALARMS
(ODU,ENABLE,STAND-ALONE)
ALARMS
ALARMS: CURRENT STORED
(PRESS ENTER)
The operator uses this menu item to view either CURRENT Alarm Status or the
STORED Alarms Log. Use the LEFT/RIGHT arrow keys, then press ENTER.
3.2.49 (ODU,ENABLE,1:1,CSAT#1,ALARMS)
CURRENT
(ODU,ENABLE,1:1,CSAT#2,ALARMS)
CURRENT
(ODU,ENABLE,STAND-ALONE,ALARMS)
CURRENT
TX = OK RX = OK
PWR SUP = OK MISC = OK
The operator uses this menu item to view CURRENT Alarm Status. This window
provides a summary of the current CSAT status, if any of the 4 items displays “FT” the
operator should view the STORED Alarms Log for details.
3.2.50 (ODU,ENABLE,1:1,CSAT#1,ALARMS)
STORED
(ODU,ENABLE,1:1,CSAT#2,ALARMS)
STORED
(ODU,ENABLE,STAND-ALONE,ALARMS)
STORED
STORED EVENTS: VIEW
CLEAR ALL (PRESS ENTER)
The operator uses this menu item to either VIEW or CLEAR the Stored Events Log using