beautypg.com

Comtech EF Data RAP-100 User Manual

Page 30

background image

RAP-100 Remote Access Panel

ODU Operation

Rev. 1

3–13

3.2.47 (ODU,ENABLE,1:1,CSAT#1,MONITOR)

PWR

SUPP2

(ODU,ENABLE,1:1,CSAT#2,MONITOR)

PWR

SUPP2

(ODU,ENABLE,STAND-ALONE,MONITOR)

PWR SUPP2

PS: +5V=5.5 -5V=-4.9


This window provides a monitor for the remaining two internal power supplies, press
ENTER.

3.2.48 (ODU,ENABLE,1:1,CSAT#1)

ALARMS

(ODU,ENABLE,1:1,CSAT#2)

ALARMS

(ODU,ENABLE,STAND-ALONE)

ALARMS

ALARMS: CURRENT STORED

(PRESS ENTER)


The operator uses this menu item to view either CURRENT Alarm Status or the
STORED Alarms Log. Use the LEFT/RIGHT arrow keys, then press ENTER.

3.2.49 (ODU,ENABLE,1:1,CSAT#1,ALARMS)

CURRENT

(ODU,ENABLE,1:1,CSAT#2,ALARMS)

CURRENT

(ODU,ENABLE,STAND-ALONE,ALARMS)

CURRENT

TX = OK RX = OK

PWR SUP = OK MISC = OK


The operator uses this menu item to view CURRENT Alarm Status. This window
provides a summary of the current CSAT status, if any of the 4 items displays “FT” the
operator should view the STORED Alarms Log for details.

3.2.50 (ODU,ENABLE,1:1,CSAT#1,ALARMS)

STORED

(ODU,ENABLE,1:1,CSAT#2,ALARMS)

STORED

(ODU,ENABLE,STAND-ALONE,ALARMS)

STORED

STORED EVENTS: VIEW

CLEAR ALL (PRESS ENTER)


The operator uses this menu item to either VIEW or CLEAR the Stored Events Log using
the LEFT/RIGHT arrow keys, then press ENTER.