Introduction

RAP-100 Remote Access Panel

1–2

Rev.

1

1.4 Getting

Started:

After the interface cable between the RAP-100 and CSAT is built and installed, simple
apply power for both units. The ‘Comm. Link’ LED on the front of the RAP-100 will be
GREEN when the two units are communicating and RED when a problem exists. If the
LED is RED go to the ‘LINK’ menu and select ‘ESTABLISH’. Select the when queried
‘RE-ESTABLISH COMM LINK?’. The RAP-100 will now attempt to communicate to
the CSAT via the global address ‘0’ at the 5 possible baud rates. Once communications
have been established the RAP-100 will direct the CSAT to address 0001 and 9600 baud.
If this does not resolve the problem first verify that the interface cable is correct then
contact Comtech EFData customer service.