beautypg.com

Comtech EF Data RAP-100 User Manual

Page 25

background image

ODU Operation

RAP-100 Remote Access Panel

3–8

Rev.

1

3.2.25 (ODU,ENABLE,1:1,CSAT#1,CONFIG,RECEIVER)

LNA

(ODU,ENABLE,1:1,CSAT#2,CONFIG,RECEIVER)

LNA

(ODU,ENABLE,STAND-ALONE,CONFIG,RECEIVER)

LNA

SELECT LNA: STATE CAL

CURR-WINDOW FAULT-LOGIC


The user is prompted to select 1 of 4 selection using the LEFT/RIGHT arrow keys, then
to press ENTER.

3.2.26 (ODU,ENABLE,1:1,CSAT#1,CONFIG,RECEIVER,LNA)

STATE

(ODU,ENABLE,1:1,CSAT#2,CONFIG,RECEIVER,LNA)

STATE

(ODU,ENABLE,STAND-ALONE,CONFIG,RECEIVER,LNA)

STATE

SELECT ODU LNA STATE:

ON OFF (PRESS ENTER)


The user is prompted to select either ON or OFF, using the LEFT/RIGHT arrow keys,
then to press ENTER. This controls whether or not the CSAT will provide LNA
POWER via the Receive RF Cable.

3.2.27 (ODU,ENABLE,1:1,CSAT#1,CONFIG,RECEIVER,LNA)

CAL

(Calibrate)

(ODU,ENABLE,1:1,CSAT#2,CONFIG,RECEIVER,LNA)

CAL

(Calibrate)

(ODU,ENABLE,STAND-ALONE,CONFIG,RECEIVER,LNA)

CAL

(Calibrate)

CALIBRATE LNA CURRENT?

CAL EXIT (PRESS ENTER)


The user is prompted to select either CAL or EXIT, using the LEFT/RIGHT arrow keys,
then to press ENTER. This provides a means to calibrate the LNA current for use with
the Current-Window function described below.

3.2.28 (ODU,ENABLE,1:1,CSAT#1,CONFIG,RECEIVER,LNA)

CURR-WINDOW

(ODU,ENABLE,1:1,CSAT#2,CONFIG,RECEIVER,LNA)

CURR-WINDOW

(ODU,ENABLE,STAND-ALONE,CONFIG,RECEIVER,LNA)

CURR-WINDOW

EDIT LNA CURRENT WINDOW:
99 % (PRESS ENTER)


The user is prompted to edit the Current Window setting using the UP/Down arrow keys,
then to press ENTER. The value will scroll between 20% and 50% to define the
allowable LNA current change before declaring a fault. Selecting 99% disables the
current window function.