beautypg.com

Comtech EF Data DD2401 User Manual

Page 64

background image

User Interfaces

DD2401 Satellite Demodulator

4-

40

MN-DD2401 - Rev. G

Mode


Opcode: <2616h>

Command a Module’s External Reference Source

<1>

External Ref.
Source

0 = Internal, 1 = External


Opcode: <261Bh>

Command a Module’s External Reference Frequency

<4>

External Ref. Freq.

Unsigned Binary Value in Hz


Opcode: <2C03h>

Command Clear all Latched Alarms (No Parameters)

Opcode: <2C04h>

Command Set Time

<1>

<1>

<1>

Hour

Minute

Second

0 - 23

0 – 59

0 – 59


Opcode: <2C05h>

Command Set Date

<1>

<1>

<1>

Year

Month


Day

0 – 99

0 – 11

0 - 30


Opcode: <2C06h>

Command Set Time and Date

<1>

<1>

<1>

<1>

<1>

<1>

Year

Month

Day

Hour

Minute

Second

0 – 99

0 – 11

0 – 30

0 – 23

0 – 59

0 – 59


Opcode: <2C07h>

Command soft reset the modem to the power-up state (no parameters).

Opcode: <2C08h>

Commend Eb/No Threshold

<1>

Eb/No
Threshold

Unsigned Binary Value, 0-99, Implied Decimal Point
0.0 through 9.9 dB


Opcode: <2C30h>

Command Module Set Default Configuration (No Parameters)

4.4.12.3

Default Values Demodulator

Opcode: <2A00h> Command a Demodulator’s Configuration