User Interfaces

DD2401 Satellite Demodulator

4-

14

MN-DD2401 - Rev. G

packet; but with the same . When the intended receiver detects a duplicate packet, the
packet is acknowledged with a response packet and internally discarded to preclude undesired
repetitive executions. If the M&C computer sends a command packet and the corresponding
response packet is lost due to a system or internal error, the computer times out and re-transmits
the same command packet with the same to the same receiver and waits once again for
an acknowledgment or a NAK packet.

To reiterate, the format of the message block is shown in Table B-4, Link Level Protocol Message
Block.

Table 4-6. Link Level Protocol Message Block

SYNC

COUNT

SOURCE

ADDRESS

DESTINATION

ADDRESS

FSN

OPCODE

DATA

BYTES

CHECKSUM


The RLLP Remote Port Packet structure is as follows:

Message format header character that defines the beginning of a

message. The character value is always 0x16. (1 byte)


Number of bytes in the field. (2 bytes)

Identifies the address of the equipment from where the message

originated. (1 byte)

Identifies the address of the equipment where the message is to be sent.
(1 byte)

Frame sequence number ensures correct packet acknowledgment and data
transfers. (1 byte)

This byte identifies the message type associated with the information

data. The equipment processes the data according to the value in this field. Return error
codes and acknowledgment are also included in this field. (2 bytes)

<...DATA...>

Information data. The number of data bytes in this field is indicated by

the value.

The modulo 256 sum of all preceding message bytes excluding the
character. (1 byte)

4.4.9 DD2401/DD2401L Opcode Command Set


The DD2401/DD2401L Opcode Command Set is listed below, separated by commands that
control the demodulator, or the entire module.

4.4.10

Demodulator Command Set

RLLP Command

Opcode

Query Demodulator All

2401h

Query Demod Latched Alarms

2406h

Query Demod Current Alarms

2409h

Query Demod Status

240Ch

Query Demod Eb/No, Input Level, Raw BER, Corrected
BER, and Frequency Offset, AGC Voltage

240Dh

Query Demod Lock Status

2437h