Comtech EF Data DD2401 User Manual
Page 42

User Interfaces
DD2401 Satellite Demodulator
4-
18
MN-DD2401 - Rev. G
<1>
<24>
<1>
<1>
*<1>
<1>
<1>
*<1>
*<1>
*<1>
*<1>
*<1>
*<1>
BER Measure
Period
Rx Circuit ID
Rx Terrestrial
Loopback
Rx Baseband
Loopback
Rx IF Loopback
Reserved
Data Invert
Async Framing
Async Baud Rate
Async Port Type
Async Terrestrial
Interface Type
Multiprotocol
Interface Card
Interface Type
G.703 Interface
Type
Unsigned Binary Number of Bits in Measurement Period, in Powers
of Ten (ex: 6 = 10
6
Bits)
24 ASCII Characters
0 = Disabled, 1 = Enabled
0 = Disabled, 1 = Enabled
0 = Disabled, 1 = Enabled
Ignore
0 = Normal, 1 = Invert
Note: The following byte applies only if an Asynchronous, IDR
or IBS Interface is installed. If not, ignore.
0 = No Framing, 1 = 1/16 Async, 2 = 1/16 IBS, 3 = 96 Kbit IDR
Note: The following byte applies only if an asynchronous
interface card is installed. If not, ignore.
0 = 1200, 1 = 2400, 2 = 4800, 3 = 9600, 4 = 19200, 5 = 50, 6 = 110,
7 = 300, 8 = 600
Note: The following byte applies only if an asynchronous
interface card is installed. If not, ignore.
0 = RS-232, 1 = RS-485
Note: The following byte applies only if an asynchronous
interface card is installed. If not, ignore.
0 = V.35, 1 = RS-422, 2 = RS-232
Note: The following byte applies only if a synchronous
Multiprotocol interface card is installed. If not, ignore.
0 = V.35, 1 = RS-422, 2 = RS-232
Note: The following byte applies only if a symmetric G.703
interface card is installed. If not, ignore.
0 = G703T1AMI, 1 = G703T1B8ZS, 2 = G703BE1, 3 = G703UE1
Note: The following byte applies to all DMD2401 modems,
regardless of interface type.