Maintenance and Malfunction Treatment

3) The surface of the treadmill should be kept clean, pull out

the power line before cleaning. You can clean the running
belt and the surface of the treadmill with a soft and wet
cloth.

4) The running belt is adjusted at factory; it may runs

defectively after transportation and use. Turn off the
treadmill before adjusting, pull the belt in the center, and
then adjust the left and right bolts in rear roller with hex
spanner (See figure ) it is better to adjust 1/2 circle once.
Then

turn

on

the

switch,

check

if

the

belt

10 runs defectively when the running speed is 4~5 km/h.

5) After using over 100hours or the lubricant between the

running board and the running belt is used up, please
lubricate the running board and adjust the running belt well.

6) After a long time of running, the belt may be longer and stuck. You should turn the left and right adjustor

bolt in rear roller clockwise at same position till the runs smoothly and freely.

Warning:
3) The safety level of the equipment can be maintained only if it is examined regularly for damage and wear,

e.g. pins, connection points.

4) Please replace defective components immediately and/or keep the equipment out of use until repair.

. Malfunction

Reason

Treatment

Cannot start the treadmill after the
power line is plugged.

1. Plug incorrectly.
2. Signal line is not inserted

correctly.

3. Safe set is not replaced.

Plug it again.

Reset it.

1. Computer displays normally, but

the treadmill can not be
operated

2. Computer displays normally, but

the belt doesn’t run, and buzzes.

Input voltage is too low.

Use it when voltage is
normal

Operating normally when non-
loading, the belt gets stuck when the
user is running on the belt.

Check if the belt is too loose.

Adjust the length of the
running belt.