15 séance indicators, 1 message led, 2 activity led – Cadac Seance User Manual
Page 31: 3 ccm present led, 4 ccm error led, 5 sam present led, 6 sam error led, 7 power led, 8 pc2 led, Séance indicators -7

Séance
3-7
Revision SE2005-2
Séance Interface 7975
6148 6pDQFH#LQGLFDWRUV
614814 0HVVDJH#/('
The yellow message LED will flash briefly when an Ethernet message arrives for the
Séance box.
614815 $FWLYLW\#/('
The green activity LED indicates that there are messages on the Ethernet interface.
614816 &&0#3UHVHQW#/('
The green SAM present LED will light when Séance/Console communications are
present.
614817 &&0#(UURU#/('
The red error led will light solidly when Séance/Console communications are not
present. It will flash when a Console related error has occurred.
614818 6$0#3UHVHQW#/('
The green SAM present LED will light when SAM/Séance communications are
present.
614819 6$0#(UURU#/('
The red error led will light solidly when SAM/Séance communications are not present.
It will flash when a SAM or Ethernet error has occurred.
61481: 3RZHU#/('
The red power LED indicates that +5Volts is present on the Séance PCB.
61481; 3&5#/('
The yellow PC2 LED is alight when the console is set to PC2.