background image

29

PENDULUM WEAVER II SETUP

INSTALLATION

The Weaver Control Module plugs into the Master Drive Unit. Use a flat blade screwdriver to firmly secure

the four corners of the module.

Remove connector cover plate from MPD-1000. Plug the Pendulum Weaver Electronics box into the front

end of the Master Drive Unit. Secure the box to the drive unit by using the four captive screws on the elec-

tronics box.

Bolt the mounting plate onto the front of the carriage, below the electronics box, and bolt the rackholder onto

the mounting plate. Insert the 14" (355 mm) rack through it.

Several different arrangements can be used to mount the gearbox on the rack and to position the welding

gun. One recommended assembly method is shown below: bolt the racks, gearbox, and clamps together as

shown in the diagram.

Finally connect the gearbox to the electronics box using the cable supplied, with 6-pin connectors on each end.