The pressure loss across the needle can be described by: 
 

∆P

k T ∅

P

1

20°

1

 
The  spring  force  in  the  upstream  membrane  valve  closes  the  valve  in  the  “zero”  flow  situation.  By 
opening the needle valve the ΔP will increase, so far that the membrane lifts up and compensates the 
spring force. In the equilibrium position the flow will be constant even when the upstream pressure (P

in

changes. However when the upstream pressure increases, it will cause a small effect on the spring force, 
which  means  that  the  ΔP  to  open  the  membrane  valve  will  be  a  little  smaller.  This  results  in  a  lower 
flow. 
 

 

In practise the deviation of the ideal straight line will be less than 0,5‐1% per bar. 

1.11 Electronics, display and 4-way button

The  MASS‐VIEW

®

    has  a  bright  graphical  OLED  display, 

clearly  visible  over  any  angle,  which  allows  reading  of 
actual flow (value and bar graph), total flow and gas type.  
The three display options can be changed using the 4‐way 
button  This  button  is  a  navigation  joystick  which  has 
UP/DOWN/LEFT/RIGHT  keys  and  a  centre  push  (ENTER) 
key. 

 
 
 

 

 

 

 

 

 

 

4‐way button