General:
Figure 1, above, shows the location of programming/navigating buttons on the face of the Altivar 11
(Belshaw P/N: VFD-0017). Figure 2 shows the navigation paths to various programming parameters.
The following has been adapted from the ATV11 Technical Manual which can be found at
http://ecatalog.squared.com/pubs/Motor%20Control/AC%20Drives/Altivar%2011/VVDED302026US.pdf
Programming:
Using Figures 1, and 2 navigate to the following programming parameters and set them as shown below
in Table 1. Items listed as default are set at the factory and should be verified.
The parameters in unshaded boxes can only be modified when the controller is stopped.
Remove jumper wire from terminal 15 to stop drive.
The parameters in shaded boxes can be modified with the controller operating or stopped.
MENU PARAMETER
SECONDARY
PARAMETER
FUNCTION SETTING
1
st
Level
ACC
Acceleration ramp time
(sec.)
3 (default)
dEC
Deceleration ramp time
(sec.)
3 (default)
LSP
Low Speed (hz)
0 (default)
HSP
High Speed (hz)
50/60 (default) based on motor
Hz
ItH
Motor thermal current
(amps)
2.1
(Set to motor nameplate amps)
Alt
Configuration of Analog
Input
5U (default)
drC
UnS
Motor voltage (volts)
230
(Set to motor nameplate
voltage)
FrS
Motor frequency (hz)
60
(Set to motor nameplate
frequency)
nCr
Motor current (amps)
2.1
(Set to motor nameplate
current)
COS
Motor power factor
.80
(Set to motor nameplate power
factor (sometimes labeled ‘pf’))
FUn
tCC
ACt
2-wire control
2c (default)
tCt
Type of 2-wire control
LEL
rrS
Reverse
operation
nO
PS2
L1A
Assignment of L1A
nO
L1b
Assignment of L1B
nO
PI
PIF
Assignment of PI
function feedback
nO (default)
rSF
Fault reset
nO (default)
bFr
Motor Frequency (hz)
60 for domestic machines
(default).
50 for AS/NZ, and CE
machines;