Belshaw Adamatic TG25 Thermoglaze User Manual
Page 37
Belshaw Bros., Inc.
• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425
Thermoglaze 25 TS
MN-1728EN
13
THERMOLIZER WILL NOT TURN ON
Possible Causes
What To Do
Power cord is not plugged in
Plug power cord into the TG control box
Fuse is blown.
Replace the 20 Amp fuse
Circuit breaker is off in the TG control
box.
• Disconnect TG from power.
• Open TG control box.
• Turn on Circuit breaker.
• Close control box.
• Reconnect to power.
THERMOLIZER WILL NOT HEAT UP
Possible Causes
What To Do
Control box power switch is not “on.”
Flip switch to “on” position.
Defective heat control.
Replace the heat control.
Loose wire or bad connection.
Repair the wire.
Defective heat element.
Replace the heat element.
Defective control box power switch.
Replace power switch.