CONVEYOR WILL NOT MOVE
Possible Causes
What To Do
Conveyor is jammed.
Check for obstruction in conveyor and remove.
GLAZER WILL NOT PUMP GLAZE (SEE FIGURE 5-1)
Glazer motor is not running.
Check to make sure the motor is running.
(See Pump Motor Will Not Run)
Glazer pump impellers are worn.
1. Disconnect power.
2. Replace impellers.
GLAZE IS MISSING THE DONUTS ON ONE SIDE OF THE GLAZE SCREEN
Glazer or glaze trough is not level.
Adjust level of glaze trough by moving set collar.
Glaze pump is running too slow.
1. Disconnect from power.
2. Open Electrical Enclosure.
3. Turn glazer speed control clockwise.
4. Close Electrical Enclosure.
THE PUMP MOTOR WILL NOT RUN
Possible Causes
What To Do
The connection of the power cord to the power
source is faulty.
Make sure the power cord is fully plugged in to a
proper power source.
The circuit breaker has been tripped.
1. Disconnect from power.
2. Open electrical enclosure.
3. Reset circuit breaker.
4. Close electrical enclosure.
THE FILL HOSE IS LEAKING
Possible Causes
What To Do
Fill hose is leaking at the connection.
Hose bracket needs adjusting or tightening.
Fill hose is leaking near the pump.
Check for missing or damaged o-ring.