LACK OF HUMIDITY OR UNEVEN HUMIDITY
Possible Causes
What To Do
Low water.
Refill water reservoir/Check water is on.
Defective humidity control.
Replace the humidity control.
Defective water heat element.
Replace the water heat element.
Restriction or sediment in the water line or
the water heat box inlet hole.
Clean out water line.
Loose wire or bad connection in humidity
circuit.
Repair loose wire or connection in
humidity circuit.
Blower is not running.
See “Blower Will Not Run” section
Doors out of alignment.
Align doors.
BLOWER WILL NOT RUN
Possible Causes
What To Do
Control box power switch is not “on.”
Flip switch to “on” position.
Defective blower motor.
Replace blower motor.
Defective control box power switch.
Replace control box power switch.
Loose wire or bad connection in blower
control circuit.
Repair loose wire or bad connection.