2 installation, Thermolizer installation, Unpacking and assembling the thermolizer – Belshaw Adamatic TG25 Thermoglaze User Manual
Page 26
Belshaw Bros., Inc.
• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425
2
MN-1728EN
Thermoglaze 25 TS
2 Installation
WARNING
To avoid electrocuting yourself or damaging
the Thermoglaze, never allow water, steam,
cleaning solution, or other liquid to enter the
electrical panels or connections
Electrical:
Model Dimensions Power
Requirements
TG25
60"L x 31W x
52"H
See data tag
Make sure that the power requirements of the
Thermoglaze, shown on the data plate, match
your power source.
Only plug in to power source that matches the
required voltage and current for the
Thermoglaze. (The Thermoglaze unit TG25
comes standard with a Hubbel 360P6W plug that
needs a 360C6W socket or equivalent for
electrical current.
Thermoglaze must be electrically grounded and
connected in compliance with the National
Electrical Code, ANSI-NFPA 70, and applicable
municipal building codes.
Do not apply electrical power to the system until
the assembly has been completed. See Section 4
for the assembly of the Thermoglaze.
WARNING
When handling Thermolizer Control Box,
keep hands and feet clear as injury may occur
if box is dropped.
Venting:
Local codes prevail. The authorities having
jurisdiction are stated in NFPA 96-1994
regarding requirements for the Thermoglaze.
Building Layouts:
Specification sheets and AutoCAD drawings for
use in developing architectural drawings can be
provided by request. Please call your Belshaw
Bros., Inc. representative for help in defining
your requirements.
Thermolizer Installation
Unpacking and Assembling the
Thermolizer
Use a forklift to transport the shipping crate to
the workstation.
1. Break down the shipping crate.
2. Remove the packing materials from the
thermolizer, including foam, tape, brown
paper, plastic, and white protective coating.
Do not remove the plastic from the
Plexiglas doors at this time.
3. Cut the bands holding the control box in
place and remove the control box from the
cabinet.
4. Remove and discard the plywood that the
control box was resting on.
5. Inspect the machine to see that no parts are
bent, scratched, or otherwise damaged. If
any damage has occurred in shipping, file a
freight claim with the shipping company
immediately.
6. Clean the humidifier water box and attach to
filtered water per plumbing codes in your