Thermolizer Cleaning
Instructions
Once a week, clean the Thermolizer as follows:
1. Remove and clean Plexiglas doors with
warm water.
2. Disconnect from power and remove control
box from cabinet.
3. Remove and clean the screen rack angles,
angle supports, and air duct.
4. Wipe the cabinet interior clean.
5. Special attention should be given to cleaning
the water box (Item 2 of Control Box Assy.,
parts list drawings). Clean the water box as
follows:
a. Turn off water to the Thermolizer
control box. (Auto-water fill only)
b. Remove water reservoir cover.
c. Empty the water reservoir pan.
d. Remove water box access cover thumb
screw and rotate access cover to open
position. (see Figure 5-1)
e. Use a rubber syringe baster to remove
sediment from the water box. Wipe the
inside of the water box with a rag.
f. Add a small amount of water to the
water reservoir pan. Water should flow
freely into the water box. If not, clean
out the water line between the water box
and the water reservoir pan. Check for
blockage at the water box inlet hole first.
g. Close water box access cover and fasten
with thumbscrew.