12. Loosen the screws that hold the

Thermostat in place under the dial. (See
photo above) You should NOT loosen the
screws all the way, or the Thermostat
might fall out.

13. If the temperature in step 6 was MORE

than 375°F (190°C), rotate the
Thermostat CLOCKWISE.

14. If the number you recorded in step 6 was

LESS than 370°F (190°C), rotate the
Thermostat COUNTER-CLOCKWISE.

15. Tighten both screws again and replace the

Temperature Control dial.

16. Connect power to the Donut Robot and

retest by repeating the process from Step
3 above.

17. If you are UNABLE to rotate the

Thermostat far enough to make the light
come on between 370° to 375°F (188° to
190°C), you should first check your
Thermometer. Get a 2

nd

thermometer and

compare the two.

18. If necessary, go back to Step 3 using the

most accurate thermometer.

19. If you are still UNABLE to rotate the

Thermostat far enough to make the light
come on between 370° to 375°F (188° to
190°C), have a qualified technician check
your fryer and if necessary replace the
thermostat. The part number is listed on
the wiring diagram attached to your
manual.