Belshaw Adamatic Mark VI Donut Robot User Manual
Page 62
Belshaw Bros., Inc.
• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425
26
MN-1032EN
Donut Robot Mark VI TS
THE CONVEYOR CHAINS DO NOT ADVANCE WHEN THE MAIN POWER IS
ON, BUT THEY DO ADVANCE WHEN THE PRIME SWITCH IS PRESSED.
Possible Causes
What To Do
WARNING
To avoid electric shock or other injury, before
doing any of the following, unplug the machine.
The red wire in the power cord is broken or
poorly connected.
Repair the cord and/or make the proper connection.
The microswitch in the power head is defective. Replace the microswitch.
The microswitch in the Donut Robot’s signal
circuit is defective.
Replace the microswitch.
THE CONVEYOR CHAINS DO NOT ADVANCE AT ALL, DO NOT ADVANCE
FAR ENOUGH, OR DO NOT ADVANCE THE SAME DISTANCE DURING
EACH CYCLE, BUT THE PILOT LIGHT DOES COME ON.
Possible Cause
What To Do
The cam in the power head is loose.
WARNING
To avoid electric shock or other injury, before
doing the following, unplug the machine.
Tighten the cam set screw.