BECKHOFF C1300 User Manual
Page 33
C1300 VME to II/O Interface Unit
Beckhoff II/O-System
Date : 18.12.95
Version : 2.01
Page 33 of 44
Funktion 0bh: Initialization of free programmable communication
This function is used to transmit the parameters, needed for initialization, to the
C1300.
channel
length
function
empty
argument
0
argument
1
argument
2
argument
3
call
09
0b
00
ssn
nt
oa 0,1
ia 0,1
channel
length
function
argument
0
comment
response
03
0b
00
ok
03
0b
01
error
ssn
signal state number
nt
number of telegrams
oa 0,1
base address output area
ia 0,1
base address input area
The base address output area defines the area in the DPRAM, where the self
defined telegrams are stored. Only address byte, control byte and four data bytes
are stored. There is no check byte stored. This is done internally by the controller.
Beginning at the base address input area address byte, control byte and entry data
are stored.