C1300 VME to II/O Interface Unit

Beckhoff II/O-System

Date : 18.12.95

Version : 2.01

Page 23 of 44

Funktion 08h : continuous transmission

This function only controls the "cycle"-LED on the modules.This way it is
possible to find out how many modules are still connected to the transmission
output of the C1300. This function is only supposed to be activated, if there is no
satisfying result from the function 0ah ( fraction test ).The only way for the
software to stop continuous transmission is a reset .

channel

length

function

argument

0

argument

1

argument

2

comment

call

02

08

response

03

08

01

constant transmission can be

stopped by reset

While continuous transmission is working the functions 05h to 07h and 0ah are
inhibited.