C1300 VME to II/O Interface Unit

Beckhoff II/O-System

Page 26 of 44

Version : 2.01

Date : 18.12.95

Funktion 0ff

h

: Wrong Function

in case there is a function call through handshake channel 0 and the function is
reserved or not available,it is returned with function 0ffh, which has as argument 0
the wrong function number.

Example:

channel

length

function

argument

0

argument

1

argument

2

comment

call

03

04

01

call of function 4
( reserved )

response

03

0ff

04