5 dismantling sequence – BECKHOFF AL2000 Linear servomotor User Manual
Page 35

Mechanical installation
7.5
Dismantling sequence
WARNING
Damage due to uncontrolled magnetic attractive forces
The dismantling sequence given in these instructions must be followed. A different se
quence can give rise to dangerous situations, and can lead to damage resulting from un
controlled magnetic attraction.
Dismantling sequence:
1. Check that there is no voltage and secure against being switched on again.
2. Disconnect the electrical cables.
3. Disconnect the hoses of the water cooling unit (if installed).
4. Move the carriage to one side. Secure the carriage in such a way as to prevent unwanted movement.
5. Cover each magnetic plate that needs to be removed with a neutralising protective plate.
6. Remove one or more magnetic plates. The distance between the magnetic plates and the coil unit dur
ing this process should not be less than 10 cm.
7. Move the carriage to the other side. Secure the carriage in such a way as to prevent unwanted move
ment.
8. Cover each magnetic plate that needs to be removed with a neutralising protective plate.
9. Remove the remaining magnetic plates.
10. Remove the coil unit from the carriage.
Linear servomotor AL2xxx
35
Version 4.0