4 handling, 1 transport, 2 packaging – BECKHOFF AL2000 Linear servomotor User Manual
Page 13: 3 storage, 4 maintenance / cleaning, 5 disposal, 4handling

Handling
4
Handling
4.1
Transport
• Climate category: 2K3 according to EN 60721
• Transport temperature: 25 °C +70 °C, max. fluctuation 20 K/hour
• Transport humidity: relative humidity 5% 95%, noncondensing
• The linear servomotor may only be transported by qualified personnel and in the manufacturer's origi
nal recyclable packaging.
• If the packaging is damaged, check the motor for visible damage. Inform the transport company and, if
necessary, the manufacturer.
4.2
Packaging
• Cardboard packaging
Motor type
Max. stacking height
AL2xxx
4.3
Storage
• Climate category
2K3 according to EN 60721
• Storage temperature:
25 °C +70 °C, max. fluctuation 20 K/hour
• Air humidity:
relative humidity 5% 95%, noncondensing
• Max. stacking height:
see table Packaging
• Storage time:
without limitation
• Store only in the manufacturer’s original recyclable packaging
4.4
Maintenance / Cleaning
• Maintenance and cleaning only by qualified personnel.
• Opening the motor invalidates the warranty.
• Clean the housing with isopropanol or similar.
Attention
Destruction of the linear servomotor
Never immerse or spray the linear servomotor.
Proper functioning of the bearings and buffers, and guidance of the movable lines, must all be tested.
4.5
Disposal
In accordance with the WEEE 2002/96/EC Directives we take old devices and accessories back for
professional disposal, provided the transport costs are taken over by the sender. Send the devices with the
note “For disposal” to:
Beckhoff Automation GmbH
Eiserstrasse 5
33415 Verl
Linear servomotor AL2xxx
13