Code 39, Code 39-pharmacode, I 2 of 5 – Datalogic Scanning MAGELLAN 8500 User Manual
Page 423
Product Reference Guide
F-7
Code 39
•
Check character must be included in label data.
•
Label length including start, stop and check characters and
excluding prefix character must meet requirements imposed by
the main scanner's fixed or variable label length control for this
symbology type.
•
Start and stop characters "*" must be included in label.
•
Prefix must be an ASCII character '*'.
•
Example : '**Code 39.TEST*'.
Code 39-Pharmacode
•
Check character must be included in label data.
•
Label length including start, stop and check characters and
excluding prefix character must meet requirements imposed by
the main scanner's fixed or variable label length control for this
symbology type.
•
Start and stop characters "*" must be included in label.
•
Prefix must be an ASCII character 'p'.
•
Example: 'p*123456789*'.
I 2 of 5
•
Check character must be included in label data.
•
Label length including check characters and excluding prefix
character must meet requirements imposed by the main scanner's
fixed or variable label length control for this symbology type.
•
Prefix must be an ASCII character 'i'.
•
Example: 'i0123456789'.