6-26

Magellan

®

8500 Scanner

Good Read Beep Length

Specifies the duration of a good read beep.

To set the good read beep length:

1. Scan the SWITCH bar code.

2. Scan the bar code, SET GOOD READ BEEP LENGTH. You’ll

need to cover any unused bar codes on this and the facing page to
ensure that the scanner reads only the bar code you intend to
scan.

3. Scan the appropriate digits from the keypad in Appendix C that

represent the desired good read beep length setting. The select-
able range is 1-255, which is the timeout in 10-millisecond incre-
ments. Pad all single and double digit numbers with leading
zeroes to yield a three-digit entry (001-255).
Examples:

001 = 10ms

005 = 50ms

040 = 400ms

250 = 2,500ms (2.5 seconds)

4. The scanner will automatically exit Programming Mode when the

appropriate amount of digits have been scanned