Scanning Features

Product Reference Guide

37

Scanning Features

Scan Mode

Selects the scan operating mode for the reader. Selections are:

Trigger Single.

When the trigger is pulled, scanning is activated until one of the following

occurs:

-

Scanning Active Time

has elapsed

- a label has been read
- the trigger is released

This mode is associated with typical handheld reader operation: when the trigger is pulled,
scanning starts and the product scans until the trigger is released, or a label is read, or the
maximum

Scanning Active Time

has elapsed.

Trigger Hold Multiple .

When the trigger is pulled, scanning starts and the product scans until

the trigger is released or

Scanning Active Time

has elapsed. Reading a label does not disable

scanning.

Double Read Timeout

prevents undesired multiple reads of the same label while in this

mode.

Trigger Pulse Multiple.

When the trigger is pulled, continuous scanning is activated until

Scanning Active Time

has elapsed or the trigger has been released and pulled again.

Double Read

Timeout

1 prevents undesired multiple reads of the same label while in this mode.

Flashing.

The reader flashes

1

on and off regardless of the trigger status. Flash rate is controlled

by

Flash On Time

and

Flash Off Time

. When Flash is ON the imager reads continuously; when

Flash is OFF scanning is deactivated.

Always On.

No trigger pull is required to read a barcode. Scanning is continually on. If the

trigger is pulled, the reader acts as if it is in

Trigger Single

Mode.

Double Read Timeout

1 prevents

undesired multiple reads of the same label while in this mode.

Stand Mode.

No trigger pull is required to read a barcode. Scanning is turned on automatically

when an item is placed in the reader’s field of view. If the trigger is pulled, the reader acts as if it
in single read mode.

Double Read Timeout

1 prevents undesired multiple reads while in this

mode.

Trigger Object Sense.

This mode is similar to Stand Mode, except that a trigger pull is required

to activate the decoder.

1. Controlled by

Flash On Time

.