Codabar — cont. codabar set length 1 – Datalogic Scanning I GD4100 User Manual
Page 241
Codabar
Product Reference Guide
239
Codabar — cont.
Codabar Set Length 1
This feature specifies one of the barcode lengths for
Codabar Length Control
. Length 1 is the
minimum label length if in
Variable Length
Mode, or the first fixed length if in
Fixed Length
Mode. Length includes the barcode’s start, stop, check and data characters. The length must
include at least one data character.
The length can be set from 3 to 50 characters.
Follow these instructions to set this feature:
1. Determine the desired character length (from 3 to 50). Pad the number with leading
zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT CODABAR LENGTH 1 SETTING.
4. Scan the appropriate two digits from the keypad in
Appendix E, Keypad
, that represent the
length setting which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See Table
29
for some examples of how to set this feature.
Table 29. Codabar Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting (and pad
with leading zeroes)
03 Characters
09 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODABAR LENGTH 1 SETTING
4
Scan Two Characters From
Appendix E, Keypad
‘0’ and ‘3’
‘0’ and ‘9’
‘1’ and ‘5’
‘5’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
If you make a mistake before the last character, scan the CANCEL
barcode to abort and not save the entry string. You can then start
again at the beginning.