beautypg.com

Datalogic Scanning I GD4100 User Manual

Page 167

background image

GS1 DataBar™ Expanded

Product Reference Guide

165

GS1 DataBar™ Expanded — cont.

GS1 DataBar™ Expanded Set Length 1

This feature specifies one of the barcode lengths for

GS1 DataBar™ Expanded Length Control

.

Length 1 is the minimum label length if in

Variable Length

Mode, or the first fixed length if in

Fixed Length

Mode. Length includes the barcode’s data characters only.

The length can be set from 1 to 74 characters.

Follow these instructions to set this feature:

1. Determine the desired character length (from 1 to 74). Pad the number with leading

zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming

Mode.

3. Scan the barcode: SELECT GS1 DataBar™ EXPANDED LENGTH 1 SETTING.

4. Scan the appropriate two digits from the keypad in

Appendix E, Keypad

, that represent the

length setting which was determined in the steps above. You will hear a two-beep indica-
tion after the last character

NOTE

.

5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming

Mode.

This completes the procedure. See Table

19

for some examples of how to set this feature.

Table 19. GS1 DataBar™ Expanded Length 1 Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

01 Character

07 Characters

52 Characters

74 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT GS1 DataBar™ EXPANDED LENGTH 1SETTING

4

Scan Two Characters From

Appendix E, Keypad

‘0’ and ‘1’

‘0’ and ‘7’

‘5’ and ‘2’

‘7’ AND ‘4’

5

Scan ENTER/EXIT PROGRAMMING MODE

If you make a mistake before the last character, scan the CANCEL
barcode to abort and not save the entry string. You can then start
again at the beginning.