beautypg.com

Datalogic Scanning I GD4100 User Manual

Page 182

background image

Symbologies

180

Gryphon™ I GD4100

Code 39 — cont.

Code 39 Set Length 1

This feature specifies one of the barcode lengths for

Code 39 Length Control

. Length 1 is the

minimum label length if in

Variable Length

Mode, or the first fixed length if in

Fixed Length

Mode. Length includes the barcode’s data characters only.

The length can be set from 0 to 50 characters.

Follow these instructions to set this feature:

1. Determine the desired character length (from 0 to 50). Pad the number with leading

zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.

2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming

Mode.

3. Scan the barcode: SELECT CODE 39 LENGTH 1 SETTING.

4. Scan the appropriate two digits from the keypad in

Appendix E, Keypad

, that represent the

length setting which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.

NOTE

5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming

Mode.

This completes the procedure. See Table

21

for some examples of how to set this feature.

Table 21. Code 39 Length 1 Setting Examples

STEP

ACTION

EXAMPLES

1

Desired Setting

00 Characters

07 Characters

15 Characters

50 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT CODE 39 LENGTH 1 SETTING

4

Scan Two Characters From

Appendix E, Keypad

‘0’ and ‘0’

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ AND ‘0’

5

Scan ENTER/EXIT PROGRAMMING MODE

If you make a mistake before the last character, scan the CANCEL
barcode to abort and not save the entry string. You can then start
again at the beginning.