Symbologies
252
Gryphon™ I GD4100
Code 11 — cont.
Code 11 Set Length 1
This feature specifies one of the barcode lengths for
Code 11 Length Control
. Length 1 is the
minimum label length if in
Variable Length
Mode, or the first fixed length if in
Fixed Length
Mode. Length includes the barcode’s check and data characters.
The length can be set from 2 to 50 characters.
Follow these instructions to set this feature:
1. Determine the desired character length (from 2 to 50). Pad the number with leading
zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming
Mode.
3. Scan the barcode: SELECT CODE 11 LENGTH 1 SETTING.
4. Scan the appropriate two digits from the keypad in
Appendix E, Keypad
, that represent the
length setting which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See Table
31
for some examples of how to set this feature.
Table 31. Code 11 Length 1 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting (pad with
leading zeroes)
02 Characters
07 Characters
15 Characters
50 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 11 LENGTH 1 SETTING
4
Scan Two Characters From
Appendix E, Keypad
‘0’ and ‘2’
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
5
Scan ENTER/EXIT PROGRAMMING MODE
If you make a mistake before the last character, scan the CANCEL
barcode to abort and not save the entry string. You can then start
again at the beginning.