P o w e r O n / O f f
1. Turn on the circuit breaker, then turn on the power
switch.
Using the Control Panel
The following table describes how to use the control panel to set up the stacker.
Indicator/Key Description
START/STOP
Enables and disables the stacker. When the stacker is disabled, the
READY light is red. The stacker does not cut or feed tags, but the
feed roller can be turned by hand. When the stacker is enabled, the
READY light is green. As tags are ready from your printer, the stacker
feeds, cuts, and stacks the tags.
FEED
Advances one tag.
MODE
Sets the stacker’s operating mode. Modes can be changed to use the
stacker with different kinds of tags or allow service procedures like
calibration to be performed. See “About the Menu Overview” for more
information about modes.
ARROW KEYS
Sets modes and toggling between options.
POWER
Indicates the power is on, when lit.
READY
Indicates the stacker is ready to cut and stack, when green.
Indicates that the stacker is disabled, when red.
FLAG
Flashes when a sensor mark is detected.
NOTCH
Flashes each time the sensor sees a tag notch, a sensor mark, or a
Swiftach hole.
ERROR
Indicates an error, when flashing. Check the display for the error
message.
LCD Display
Shows error messages and mode settings.
Circuit Breaker
Power Switch