Error
Description/Action
854
Invalid table (string and numeric) data or not enough flash memory
for the script. Check the data. Format flash memory and download
the script using the COPY command from DOS or the ADK2
software.
855
Invalid start/clear command. The script is missing the start or clear
command {S space}.
856
Invalid quit command. The script is missing the quit command
{Q space}
.
857
Illegal command in the script. Your script may include commands
that have been removed from the ADK2 scripting language. Only
the commands listed in this manual are valid.
858
Check sum error. Each packet has a four-digit checksum at the
beginning of the packet. Compile the script again using the ADK2
software.
859
Script download buffer overflow. The image buffer is used as the
SCRATCH buffer. Increase the size of the image buffer.
T r o u b l e s h o o t i n g
Use the following information to help correct some problems that may occur.
Problem
Action
When downloading a script, the
printer errors.
Check the available flash memory. See
“Checking Available Flash Memory.”
Format flash memory. Clear NVRAM.
After downloading a script, the
script does not appear to be
loaded.
Try formatting flash memory and download
the script again.