To enable or disable status polling and immediate commands while running in 
Script mode: 
1.
From the Script Menu, press l or r until you see
 SCRIPTS 
l Status Polling r 
OR
 SCRIPTS 
l Immed Command 
2.
Press Enter/Pause.
 Enable Polling? 
 No r 
OR
 Enable Immed? 
 No r 
3.
Use l or r to select either “Yes” or “No” and press Enter/Pause. The default 
is “No.” 
E r r o r M e s s a g e s
You may receive the following errors when using a script.
Error
Description/Action
850
Invalid script packet or not enough flash memory for the script. The 
script download failed. Format flash memory and download the 
script using the COPY command from DOS or the ADK2 software. 
851
Invalid lookup table or not enough flash memory for the script. The 
lookup table download failed. Check the data in the lookup table. 
Format flash memory and download the script using the COPY 
command from DOS or the ADK2 software. 
852
Invalid buffer definition packet or not enough flash memory for the 
script. One or more of the following buffers were invalid: input 
buffer, temporary buffer, lookup buffer, printer, or array buffer. 
Check the buffer definitions. Format flash memory and download 
the script using the COPY command from DOS or the ADK2 
software. 
853
Invalid version string or not enough flash memory for the script. The 
version information in the APPVERSION command is missing or 
invalid. Make sure the information is enclosed in double quotation 
marks. Format flash memory and download the script using the 
COPY command from DOS or the ADK2 software. 