4.6.4
HPI Logging Support
The actions taken by the HPI daemon are written to a log file. The path and name of the log file
is defined in the configuration file bbs-hpib.conf.
To control what kind of information is written to the log file, the log control can be used.
Refer to the header file MotorolaHpi.h for used defines.
StateUnion.Discr
ete
Bits 7..0:
0
: Short POST
1
: Long POST
Bits 15..8
: CPU complex number
Bits 31..16
: Reserved
The POST type value is
specified in the least
significant byte.
The CPU number (or SET
Selector byte) is normally
zero. However, for blades
that support more than one
CPU complex, the processor
complex is identified with
this field.
Table 4-15 POST Type HPI Control Sate Values (continued)
SaGPISateT
Value
Notes
Table 4-16 Log RDR
SaHpiRdrT
Value
RecordId
Assigned by HPI
RdrType
SAHPI_CTRL_RDR
Entity
The same entity as logical shelf resource
RdrTypeUnion
Defined in next table
IdString
MOTHPI_CTRL_NAME_LOG
found in MotorolaHpi.h