3 hpi domain events, Table 4-9, Domain connection sensor reading – Artesyn System Management Interface Based on HPI-B 2.0(Centellis 4620/4440) User's Guide (June 2014) User Manual
Page 48: Table 4-10, Domain connection sensor events, Hpi domain events, Using hpi-b

Using HPI-B
System Management Interface Based on BBS HPI-B 2.0 (Centellis 4620/4440) User’s Guide (6806800P21D)
48
4.4.3.3
HPI Domain Events
Depending on the connection status, the Domain Connection sensor can throw events. The
following table provides details.
Category
SAHPI_EC_AVAILABILITY
EventCtrl
SAHPI_SEC_PER_EVENT
Events
SAHPI_ES_ON_LINE | SAHPI_ES_OFF_LINE
Ignore
SAHPI_FALSE
DataFormat - ReadingFormats
SAHPI_SRF_EVENT_STATE
DataFormat - IsNumeric
SAHPI_FALSE
DataFormat - IsThreshold
SAHPI_FALSE
Oem
0
Table 4-9 Domain Connection Sensor Reading
SaHpiSensorReadingT
Value
ValuesPresent
SAHPI_SRF_EVENT_STATE
EventStatus - SensorStatus
SAHPI_SENSTAT_EVENTS_ENABLED |
SAHPI_SENSTAT_SCAN_ENABLED
AssertEvents
SAHPI_ES_ON_LINE
for a connection to a shelf
SAHPI_ES_OFF_LINE
when there is no
connection to a shelf
Table 4-8 Domain Connection Sensor (continued)
SaHpiSensorRecT
Value
Table 4-10 Domain Connection Sensor Events
Event
Description
SAHPI_ES_OFF_LINE
No connection
SAHPI_ES_ON_LINE
Connection is established. Only now is the
domain of the shelf accessible.