4.6.7
NETWORK
EthLinkTest: Verifies Ethernet device (for example: eth0, eth1, eth2, etc...) link status
(active/inactive) and also captures various statistics of Ethernet device.
FloodPingTest: Uses the ICMP protocol’s mandatory ECHO_REQUEST datagram to elicit
an ICMP_ECHO_RESPONSE from a host or gateway.
EthStatsTest: Tests basic network packet consistency, that is, checks network Rx, Tx
errors, generates a warning if errors are less than or equal to 100 and marks the test as fail
if number of errors are more than 100.
NetworkCntlrTest: Verifies random data transmitted and also the data received for each
configured network device. It verifies only Ethernet and token ring devices that are
configured and active. The asynchronous devices are not verified.
NetworkAdapterTest: Executes adapter selftest (BIST) on the specified ethernet device.
SfpDetectionTest: Enumerates all SFP modules connected to SFP ports of blade and their
operational speeds.
NetworkThroughputServ: Starts the server for network throughput testing.
NetworkThroughput: Tests the network throughput.
NetworkTxBenchMark: Checks the transmission rate of interface.
- ViewCheck on PrAMC-7311 Installation and Use (November 2014) ViewCheck on ATCA-7370 Installation and Use (November 2014) ViewCheck on ATCA-7470/7475 Installation and Use (September 2014) ViewCheck on ATCA-F140 Installation and Use (September 2014) ViewCheck on ATCA-F140 Installation and Use (November 2014) ViewCheck on PrAMC-7311 Installation and Use (September 2014) ViewCheck on ATCA-7470/7475 Installation and Use (May 2014) ViewCheck on ATCA-9405 Installation and Use (May 2014) ViewCheck on ATCA-7480 Installation and Use (April 2015) ViewCheck on ATCA-9405 Installation and Use (November 2014) ViewCheck on ATCA-9405 Installation and Use (September 2014) ViewCheck on PrAMC-7311 Installation and Use (May 2014) ViewCheck on ATCA-7370 Installation and Use (April 2014)