beautypg.com

1 connectivity, 2 front-blade port mapping, 3 bcm8727 configuration flash – Artesyn RTM ATCA-F140 Installation and Use (July 2014) User Manual

Page 39: 4 transmitter control, Figure 4-3, Fabric 10 gb interconnect, Functional description

background image

Functional Description

RTM-ATCA-F140 Installation and Use (6806800M97F)

39

4.4.1

Connectivity

The two 10Gbps XAUI ports from the front blade base switch connect to a BCM8727 dual
XAUI-to-SFI PHY which then connect to two individual SFP+ connectors using an SFI interface
as shown in

Figure 4-3

. The RTM-ATCA-F140 includes 0.1μF AC-coupling capacitors on the XAUI

inputs from the front blade. Similarly, capacitors are expected to be provided on the front
blade for signals from the RTM. The SFP+ specification requires AC-coupling capacitors in the
module so they are not needed on the board SFI interface.

4.4.2

Front-Blade Port Mapping

The two base channel ports connect to the front blade ports BIX_XG0 and BIX_XG1. These
ports connect directly to dedicated ports on the ATCA-F140 front blade base switch. BIX_XG0
is connected to BCM8727 channel 2 while BIX_XG1 is connected to BCM8727 channel 1.

4.4.3

BCM8727 Configuration Flash

The BCM8727 requires an external SPI Flash to store microcode for the internal microcontroller.
A single SPI Flash is connected to the FPGA and the SPI bus from the BCM8727 is similarly
connected to the FPGA. Register settings in the FPGA allow the BCM8727 to connect to the SPI
Flash as well as provide a programming port.

4.4.4

Transmitter Control

The TXONOFF signals on the BCM8727 are individually connected to the RTM FPGA which
allows them to be driven under software control. This enables software to enable and disable
the SFP+ optical outputs.

Figure 4-3

Fabric 10 GB Interconnect

DUAL PHY

BCM8727

2x SFP+

2x SFI

2x 10GbE to Base Switch (XAUI)

Front Panel

Base Switch

Zone 3 Connector