Hardware Preparation and Installation

RTM-ATCA-F140 Installation and Use (6806800M97F)

22

2.4

RTM Installation and Removal

The RTM is fully compatible to the AdvancedTCA standard and is designed to be used in
AdvancedTCA shelves.

Airflow Impedance

An ATCA RTM shall present less
than 0.1 inches water back-
pressure at 5 CFM airflow at sea
level.

Temperature

25°C when cooled by an even
airflow of 2.2 CFM

-40°C to 85°C

0°C to 40°C when cooled by an
even airflow of 3.0 CFM

-5°C to 55°C when cooled by an
even airflow of 5.0 CFM

Temperature change

+/- 0.5°C/min

+/- 1°C/min

Relative humidity

5% to 95% non-condensing at
40°C

5% to 95% non-condensing at
40°C

Altitude

-300m to 1,800m at 40°C

-300m to 13,000m

1,800m to 4,000m at 30°C

Between 106 Kpa and 70 Kpa
air pressure

Table 2-1 Environmental Conditions (continued)

Requirement

Operating

Non-Operating